Glass Fiber Braided, Flat Type
Heat Resistant Usage, Glass Type

Product Type
Glass fiber insulated, Glass fiber sheathed. Heat resistant flat type
Features
– Heat and chemical resistant
– Not suitable for outdoor or humid environment
Application Standards
– IEC 6058433 / ASTM E230 / ANSI MC96.1
– KS C 1609: Thermocouple Extension & Compensating Cables
Materials & Structure
① Conductor: Depends on thermocouple (KX, JX, EX, TX, RX, NX)
② Insulation: Glass fiber
③ Sheath: Glass fiber
– ANSI, IEC, JIS Color code available
Data Sheet
Heading #1 | ||||||
---|---|---|---|---|---|---|
Conductor | Insulation Thickness
(mm) | Sheath Thicknees
(mm) | Overall Diameter
(mm) | Insulation resistance (MΩ/Km)
| ||
SQMM | AWG | No./mm | ||||
0.5 | – | 7/0.3 | 0.32 | 0.35 | 2.3 X 3.8 | Min.5 |
1.25 | – | 7/0.45 | 0.32 | 0.35 | 2.7 X 4.7 | Min.5 |
1.5 | – | 7/0.53 | 0.32 | 0.35 | 3.0 X 5.2 | Min.5 |
2.0 | – | 7/0.6 | 0.32 | 0.35 | 3.2 X 5.6 | Min.5 |
– | 16 | 1/1.29 | 0.32 | 0.35 | 2.7 X 4.6 | Min.5 |
– | 20 | 1/0.81 | 0.32 | 0.35 | 2.3 X 3.8 | Min.5 |
Glass Fiber Braided, Flat Type with Inner Shield
Heat Resistant Usage, Glass Type with Shield

Product Type
Braided copper inner shield, Glass fiber insulated, Glass fiber sheathed. Heat resistant flat type
Features
– Effective noise reduction
– Heat and chemical resistant.
– Not suitable for outdoor or humid environment.
Application Standards
– IEC 6058433 / ASTM E230 / ANSI MC96.1
– KS C 1609: Thermocouple Extension & Compensating Cables
Materials & Structure
① Conductor: Depends on thermocouple (KX, JX, EX, TX, RX, NX)
② Insulation: Glass fiber
③ Shield: Tin Plated Copper braided
④ Sheath: Glass fiber
– ANSI, IEC, JIS Color code available
Data Sheet
Heading #1 | |||||||
---|---|---|---|---|---|---|---|
Conductor | Insulation Thickness
(mm) | Shield (mm) | Sheath Thicknees
(mm) | Overall Diameter
(mm) | Insulation resistance (MΩ/Km)
| ||
SQMM | AWG | No./mm | |||||
0.5 | – | 7/0.3 | 0.32 | 0.3 | 0.35 | 2.9 X 4.4 | Min.5 |
1.25 | – | 7/0.45 | 0.32 | 0.3 | 0.35 | 3.3 X 5.3 | Min.5 |
1.5 | – | 7/0.53 | 0.32 | 0.3 | 0.35 | 3.6 X 5.8 | Min.5 |
2.0 | – | 7/0.6 | 0.32 | 0.3 | 0.35 | 3.8 X 6.2 | Min.5 |
– | 16 | 1/1.29 | 0.32 | 0.3 | 0.35 | 3.3 X 5.2 | Min.5 |
– | 20 | 1/0.81 | 0.32 | 0.3 | 0.35 | 2.8 X 4.2 | Min.50 |
Glass Fiber Braided, Flat Type with Outer Shield
Heat Resistant Usage, Glass Fiber Type with Shield

Product Type
Braided copper outer shield, Glass fiber insulated, Glass fiber sheathed. Heat resistant flat type
Features
– Effective noise reduction
– Heat and chemical resistant.
– Not suitable for outdoor or humid environment.
Application Standards
– IEC 6058433 / ASTM E230 / ANSI MC96.1
– KS C 1609: Thermocouple Extension & Compensating Cables
Materials & Structure
① Conductor: Depends on thermocouple (KX, JX, EX, TX, VX, RX, NX)
② Insulation: Glass fiber, Color code: + Red, – White
③ Sheath: Glass fiber, Color code: See Color Code table
④ Shield: Tin Plated Copper braided
– ANSI, IEC, JIS Color code available
Data Sheet
Heading #1 | |||||||
---|---|---|---|---|---|---|---|
Conductor | Insulation Thickness
(mm) | Sheath Thicknees
(mm) | Shield (mm) | Overall Diameter
(mm) | Insulation resistance (MΩ/Km)
| ||
SQMM | AWG | No./mm | |||||
0.5 | – | 7/0.3 | 0.32 | 0.35 | 0.3 | 2.9 X 4.4 | Min.5 |
1.25 | – | 7/0.45 | 0.32 | 0.35 | 0.3 | 3.3 X 5.3 | Min.5 |
1.5 | – | 7/0.53 | 0.32 | 0.35 | 0.3 | 3.6 X 5.8 | Min.5 |
2.0 | – | 7/0.6 | 0.32 | 0.35 | 0.3 | 3.8 X 6.2 | Min.5 |
– | 16 | 1/1.29 | 0.32 | 0.35 | 0.3 | 3.3 X 5.2 | Min.5 |
– | 20 | 1/0.81 | 0.32 | 0.35 | 0.3 | 2.8 X 4.2 | Min.50 |