UL Type PLTC (UL105℃, 300V)
General Usage, HR-PVC Type with UL Listed

Product Type
UL Type PLTC (UL105℃, 300V)
Features
HR-PVC(UL105’C) insulation/sheath product is applicable to instrument cables and thermocouple cables in environments with various conditions such as power plants, petrochemical plants, etc.
Application Standards
Standard for safety power limited circuit cables, UL 13
Certificate No. 2010802-E487787
Materials & Structure
① Conductor: Depends on thermocouple (KX, JX, EX, TX, VX, RX, NX)
② Conductor size : 14AWG-22AWG awg (0.3SQMM-2.0SQMM)
③ Insulation & Sheath : UL 105°C grade heat-resistant PVC
④ Shield: SB(Tinned-Copper), AMS(Al/mylar tape)
⑤ Number of Pair : 1Pair – 30Pair
Data Sheet
FR Rating : VW-1 Flame test, Vertical Tray Flame Test(UL1685)
Environmental Characteristics : Sun-Light resistance, Oil-Resistance Ⅰ,Ⅱ, Wet Location
UL Type PLTC (UL150℃, 300V)
Heat Resistant Usage, Teflon, Type with UL Listed

Product Type
UL Type PLTC (UL150℃, 300V)
Features
Fluororesin(FEP) insulation/sheath product is applicable to instrument cables and thermocouple cables in environments with various conditions such as power plants, petrochemical plants, etc.
Application Standards
Standard for safety power limited circuit cables
UL 13
Certificate No. 20190604-E487787
Materials & Structure
① Conductor: Depends on thermocouple (KX, JX, EX, TX, VX, RX, NX)
② Conductor size : 14AWG-22AWG awg (0.3SQMM-2.0SQMM)
③ Insulation & Sheath : Fluororesin(FEP)
④ Shield: SB(Tinned-Copper), AMS(Al/mylar tape)
⑤ Number of Pair : 1Pair – 30Pair
Data Sheet
FR Rating : VW-1 Flame test, Vertical Tray Flame Test(UL1685)
Environmental Characteristics : Oil-Resistance Ⅰ,Ⅱ, Wet Location
UL Type PLTC (UL200℃, 300V)
Heat Resistant Usage, Teflon, Type with UL Listed

Product Type
UL Type PLTC (UL200℃, 300V)
Features
UL200°C grade Fluororesin(FEP) insulation/sheath product is applicable to instrument cables and thermocouple cables in environments with various conditions such as power plants, petrochemical plants, etc.
Application Standards
Standard for safety power limited circuit cables
UL 13Certificate No. 20191029-E487787
Materials & Structure
① Conductor: Depends on thermocouple (KX, JX, EX, TX, VX, RX, NX)
② Conductor size : 14AWG-22AWG awg (0.3SQMM-2.0SQMM)
③ Insulation & Sheath :UL200°C grade Fluororesin(FEP)
④ Shield: SB(Tinned-Copper), AMS(Al/mylar tape)
⑤ Number of Pair : 1Pair – 30Pair
Data Sheet
FR Rating : VW-1 Flame test, Vertical Tray Flame Test(UL1685)
Environmental Characteristics : Oil-Resistance Ⅰ,Ⅱ, Wet Location
UL AWM Style 21974 (UL150℃, 300V)
Heat Resistant Usage, Teflon, Type with UL Listed

Product Type
UL AWM Style 21974 (UL150℃, 300V)
Features
It is applied to FEP insulated/sheathed multi-heat-resistance wires and thermocouple cables is used in environments requiring heat resistace, chemical resistance and oil resistance.
Application Standards
UL 758 & 1581
Materials & Structure
①Conductor: Tin Plated Copper
Depends on thermocouple (KX, JX, EX, TX, VX, RX, NX)
②Conductor Size: 28AWG – 14AWG (0.08SQ – 2.0SQ)
③Insulation/Sheath: Fluororesin(FEP)
④Shield(Option): SB(Tinned Copper Braided), AMS(Al/Mylar Tape)
⑤Pairing: Core Type(1C – 30C)
Pair Type (1Pair – 20 Pair)
*Overall Size: Max. 24mm
Data Sheet